{"id":160673,"date":"2025-02-05T17:19:13","date_gmt":"2025-02-05T16:19:13","guid":{"rendered":"https:\/\/cofem.com\/producto\/fire-extinguishing-system-clvr02ext\/"},"modified":"2025-07-05T09:16:54","modified_gmt":"2025-07-05T07:16:54","slug":"fire-extinguishing-system-clvr02ext","status":"publish","type":"producto","link":"https:\/\/cofem.com\/en\/producto\/fire-extinguishing-system-clvr02ext\/","title":{"rendered":"Fire extinguishing system CLVR02EXT"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row unlock_row_content=&#8221;yes&#8221; row_height_percent=&#8221;0&#8243; override_padding=&#8221;yes&#8221; h_padding=&#8221;2&#8243; top_padding=&#8221;2&#8243; bottom_padding=&#8221;2&#8243; back_color=&#8221;color-xsdn&#8221; overlay_alpha=&#8221;50&#8243; equal_height=&#8221;yes&#8221; gutter_size=&#8221;0&#8243; column_width_percent=&#8221;100&#8243; shift_y=&#8221;0&#8243; z_index=&#8221;0&#8243; content_parallax=&#8221;0&#8243; uncode_shortcode_id=&#8221;660593&#8243; back_color_type=&#8221;uncode-palette&#8221;][vc_column column_width_percent=&#8221;100&#8243; position_vertical=&#8221;middle&#8221; align_horizontal=&#8221;align_center&#8221; gutter_size=&#8221;0&#8243; override_padding=&#8221;yes&#8221; column_padding=&#8221;0&#8243; overlay_alpha=&#8221;50&#8243; shift_x=&#8221;0&#8243; shift_y=&#8221;0&#8243; shift_y_down=&#8221;0&#8243; z_index=&#8221;0&#8243; medium_width=&#8221;0&#8243; mobile_width=&#8221;0&#8243; width=&#8221;1\/2&#8243; uncode_shortcode_id=&#8221;616923&#8243; back_color_type=&#8221;uncode-solid&#8221; back_color_solid=&#8221;#f7f7f7&#8243;][vc_single_image media=&#8221;354&#8243; media_width_percent=&#8221;62&#8243; alignment=&#8221;center&#8221; uncode_shortcode_id=&#8221;165059&#8243;][\/vc_column][vc_column column_width_percent=&#8221;100&#8243; position_vertical=&#8221;middle&#8221; gutter_size=&#8221;3&#8243; override_padding=&#8221;yes&#8221; column_padding=&#8221;3&#8243; overlay_alpha=&#8221;50&#8243; shift_x=&#8221;0&#8243; shift_y=&#8221;0&#8243; shift_y_down=&#8221;0&#8243; z_index=&#8221;0&#8243; medium_width=&#8221;0&#8243; mobile_width=&#8221;0&#8243; width=&#8221;1\/2&#8243; uncode_shortcode_id=&#8221;104981&#8243;][vc_custom_heading text_color=&#8221;color-116820&#8243; text_size=&#8221;h1&#8243; text_weight=&#8221;300&#8243; uncode_shortcode_id=&#8221;175109&#8243; text_color_type=&#8221;uncode-palette&#8221;]<strong>Fire extinguishing system<\/strong> CLVR02EXT[\/vc_custom_heading][vc_column_text text_lead=&#8221;yes&#8221; text_color=&#8221;color-wvjs&#8221; uncode_shortcode_id=&#8221;973133&#8243; text_color_type=&#8221;uncode-palette&#8221;]<\/p>\n<p class=\"p-cata-descrip\"><strong>Conventional<\/strong> automatic <strong>fire detection and alarm<\/strong> system with extinguishing functionality.<\/p>\n<p class=\"p-cata-descrip\">CLVR 02EXT: Control panel with 2 zones with Extinction functionality.<\/p>\n<p class=\"p-cata-descrip\">The control panel also incorporates a third zone that can be configured as a conventional zone independent of the extinguishing zone in order to be able to protect a small area close to the flooding\/extinguishing area against fire, or to allow the supervision of an external fire protection system indicating a fault, such as a pressure switch contact.<\/p>\n<p class=\"p-cata-descrip\">The characteristics of CLVR plants are common to all models.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row unlock_row_content=&#8221;yes&#8221; row_height_percent=&#8221;0&#8243; override_padding=&#8221;yes&#8221; h_padding=&#8221;2&#8243; top_padding=&#8221;1&#8243; bottom_padding=&#8221;2&#8243; back_color=&#8221;color-xsdn&#8221; overlay_alpha=&#8221;50&#8243; equal_height=&#8221;yes&#8221; gutter_size=&#8221;0&#8243; column_width_percent=&#8221;100&#8243; shift_y=&#8221;0&#8243; z_index=&#8221;0&#8243; content_parallax=&#8221;0&#8243; uncode_shortcode_id=&#8221;528429&#8243; back_color_type=&#8221;uncode-palette&#8221;][vc_column column_width_percent=&#8221;100&#8243; position_horizontal=&#8221;left&#8221; gutter_size=&#8221;3&#8243; override_padding=&#8221;yes&#8221; column_padding=&#8221;3&#8243; back_color=&#8221;color-xsdn&#8221; overlay_alpha=&#8221;50&#8243; shift_x=&#8221;0&#8243; shift_y=&#8221;0&#8243; shift_y_down=&#8221;0&#8243; z_index=&#8221;0&#8243; medium_width=&#8221;0&#8243; mobile_width=&#8221;0&#8243; width=&#8221;1\/2&#8243; uncode_shortcode_id=&#8221;166695&#8243; back_color_type=&#8221;uncode-palette&#8221;][vc_custom_heading text_color=&#8221;color-116820&#8243; text_weight=&#8221;300&#8243; uncode_shortcode_id=&#8221;126922&#8243; text_color_type=&#8221;uncode-palette&#8221;]<strong>Key features<\/strong>[\/vc_custom_heading][vc_accordion gutter_simple=&#8221;0&#8243; uncode_shortcode_id=&#8221;77982309&#8243; active_tab=&#8221;off&#8221;][vc_accordion_tab gutter_size=&#8221;2&#8243; column_padding=&#8221;2&#8243; title=&#8221;Technical Data&#8221; tab_id=&#8221;17452324239723-1-381&#8243;][vc_column_text uncode_shortcode_id=&#8221;667704&#8243;]<\/p>\n<ul class=\"p-cata-descrip\">\n<li>Control panel with 2 zones with extinguishing functionality for use with conventional detectors and pushbuttons.<\/li>\n<li>Additional third zone can be configured as a fire detection and alarm zone for conventional detectors and push buttons or as a supervisory input for an external fire protection system.<\/li>\n<li>Same technical features as conventional CLVR control panels (2 general siren outputs, 1 alarm output, 1 fault output, 2 30 Vdc outputs, test mode, threshold configuration, metal box, etc.).<\/li>\n<li>3 Extinguishing modes of operation:\n<ul>\n<li>Normal Mode: Extinction pre-warning output R1 is activated when Zone 1 or Zone 2 is in alarm state.<\/li>\n<li>Consecutive Mode: Output R1 is activated intermittently (1s with Zone 1 or Zone 2 in alarm state, 0.5s with Zones 1 and 2 in alarm state, and continues once the delay of the extinction output R2 has expired).<\/li>\n<li>Simultaneous Mode: Output R1 is activated with Zone 1 and 2 in alarm state.<\/li>\n<\/ul>\n<\/li>\n<li>1 extinguishing stop key and 1 extinguishing activation key on the control panel.<\/li>\n<li>Possibility of installing manual stop and fire extinguishing pushbuttons in the flooding zone.<\/li>\n<li>1 extinction output (named as &#8220;R2&#8221;) supervised, delayable between 0 and 60s, and protected by a resettable fuse.<\/li>\n<li>Delay of reset release after extinguishing activation programmable between 0 and 30 minutes.<\/li>\n<li>MODBUS protocol with RS485 output on request.<\/li>\n<li>Possibility of ON-LINE software on PC using MODBUS functionality.<\/li>\n<li>CONTACTID on demand.<\/li>\n<li>Certified according to EN 54-2, EN 54-4 and EN 12094-1 with CE marking.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_accordion_tab][\/vc_accordion][\/vc_column][vc_column column_width_percent=&#8221;100&#8243; position_horizontal=&#8221;left&#8221; gutter_size=&#8221;3&#8243; override_padding=&#8221;yes&#8221; column_padding=&#8221;0&#8243; overlay_alpha=&#8221;50&#8243; shift_x=&#8221;0&#8243; shift_y=&#8221;0&#8243; shift_y_down=&#8221;0&#8243; z_index=&#8221;0&#8243; medium_width=&#8221;0&#8243; mobile_width=&#8221;0&#8243; width=&#8221;1\/2&#8243; uncode_shortcode_id=&#8221;730642&#8243;][uncode_block id=&#8221;157473&#8243; inside_column=&#8221;yes&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row unlock_row_content=&#8221;yes&#8221; row_height_percent=&#8221;0&#8243; override_padding=&#8221;yes&#8221; h_padding=&#8221;2&#8243; top_padding=&#8221;2&#8243; bottom_padding=&#8221;2&#8243; back_color=&#8221;color-xsdn&#8221; overlay_alpha=&#8221;50&#8243; equal_height=&#8221;yes&#8221; gutter_size=&#8221;0&#8243; column_width_percent=&#8221;100&#8243; shift_y=&#8221;0&#8243; z_index=&#8221;0&#8243; content_parallax=&#8221;0&#8243; uncode_shortcode_id=&#8221;660593&#8243; back_color_type=&#8221;uncode-palette&#8221;][vc_column column_width_percent=&#8221;100&#8243; position_vertical=&#8221;middle&#8221; align_horizontal=&#8221;align_center&#8221; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":354,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"sistema":[114],"tipo":[116],"class_list":["post-160673","producto","type-producto","status-publish","format-standard","has-post-thumbnail","hentry","sistema-fire-extinguishing-systems-en","tipo-central-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/producto\/160673","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/producto"}],"about":[{"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/types\/producto"}],"author":[{"embeddable":true,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/comments?post=160673"}],"version-history":[{"count":0,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/producto\/160673\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/media\/354"}],"wp:attachment":[{"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/media?parent=160673"}],"wp:term":[{"taxonomy":"sistema","embeddable":true,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/sistema?post=160673"},{"taxonomy":"tipo","embeddable":true,"href":"https:\/\/cofem.com\/en\/wp-json\/wp\/v2\/tipo?post=160673"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}