Skip to main content

Accessory and battery case C88Y

Accessory and battery case C88Y

Box to contain the accessories and batteries of the fire detection and alarm system when they cannot be placed inside the fire panel.

Key features

  • Metallic box painted in white color.
  • Dimensions: 424 x 330 x 160 mm (with cover).

Technical Data Sheets

Zócalo para detectores D50Z0 y D50ZAL

Socket for detectors D50ZO and D50ZAL

Zócalo para detectores D50Z0 y D50ZAL

Socket for detectors D50Z0 and D50ZAL

Socket for fire detection and alarm detectors of the A50 and C50 range.

There are 2 versions: with low socket or with high socket (prepared for connection with 20 mm diameter pipe).

Technical Data Sheets

Base con alarma direccionable A50ZSLDR

Addressable alarm base A50ZSLDR

Base con alarma direccionable A50ZSLDR

A50ZSLDR Addressable Alarm Base, Integrated visual and audible security

The A50ZSLDR addressable base redefines fire detection system integration, combining algorithmic addressable detection with audible and visual alarm in a single device. Designed to work with A50 detectors incorporating SIRDR functionality, this base acts as a relay associated with the detector, activating both the siren and the light signal when an alarm is detected.

Powered directly from the loop, the A50ZSLDR offers a clean and efficient installation without the need for external power supplies. Its certification to EN 54-23 for visual signaling and EN 54-3 for audible signaling ensures reliable and compliant performance in the most demanding environments.

Designed for spaces where immediate and multifunctional alerting is crucial, such as hotel rooms, residences or areas with public access, the A50ZSLDR base ensures that alarms are perceived by both sound and light, facilitating evacuation even in conditions of reduced visibility or in the presence of hearing impaired people.

Key features

  • Power supply: 18-30 V with polarity.

  • Standby consumption: 0 mA.

  • Consumption in alarm:

    • A50ZSDDR: 5 mA (low volume) / 6 mA (high volume).

    • A50ZSLDR: 19 mA (low volume) / 20 mA (high volume).

  • Operating temperature: -10 °C to +55 °C.

  • Dimensions: Ø112 × 43 mm (without detector).

  • Protection: IP21C.

  • Sound power: Low volume: 90 dB; High volume: 96 dB (measured at 1 meter).

  • Tones: 31 types selectable by microswitches.

  • Certifications:

    • A50ZSDDR: EN 54-3.

    • A50ZSLDR: EN 54-3 and EN 54-23.

  • Flash: 0.5 Hz (60 ms).

Technical Data Sheets

Indicador de acción remoto PIAL

PIAL remote action indicator

Indicador de acción remoto PIAL

PIAL remote action indicator: instant visibility where it’s needed most.

Cofem’s PIAL remote action indicator is the perfect solution for fire detection systems where visibility of the detector is limited or non-existent. Designed to clearly replicate the alarm signal, its steady red light activates when one of the system’s detectors triggers an alarm, providing an unmistakable signal that is visible from a distance.

It is ideal for use in spaces such as false ceilings, hard-to-reach areas or hotel rooms, where it makes it easy to quickly identify the location of an alarm without having to walk long distances or visually inspect each detector. Installing it on door frames or nearby walls makes it an effective tool for a swift and safe response.

Easy to install and adapt to standard mechanism boxes, the PIAL combines functionality with simplicity: technology that enhances the system’s visibility without complicating installation.

Key features

  • Alarm status can be identified in any perpendicular direction at its installation.
  • Easy connection, with polarity.
  • Can be adapted to the conduit boxes and switchgear.
  • The red light is produced by two LEDs, increasing reliability against failure of any of them.
  • Manufactured in heat-resistant ABS. Base and lid are white, red viewer.

Technical Data Sheets

Senalizacion sistema co

Signaling CO system

Senalizacion sistema co

Signaling CO system

When the concentration of CO/NO2 accumulated in the room is high enough to be dangerous for people, the COsensor detection centers activate the alarm output.

The function of these sirens is to warn the occupants to leave and not to enter until the alarm stops.

Key features

  • Operating Voltage 10.8 – 28 Vdc
  • Consumption 90 mA max.
  • Buzzer YES (98 dB at 1 m)
  • Operating temperature -10ºC to 50ºC
  • Dimensions 365 x 180 x 50 mm

Technical Data Sheets

Zócalo adaptador A30XBI

A30XBI adapter socket

Zócalo adaptador A30XBI

A30XBI adapter socket

To facilitate the task of upgrading the TC25/A system to the Lyon system (and in general, the conventional system), Cofem has an “interconnection base”, which allows the detectors of the analog and conventional system to be placed directly on the sockets of superior systems without the need to change or rewire the sockets.

In this way, if the wiring and sockets of the installation are in good condition, a quick, simple and very economical upgrade of the system can be carried out, based on the replacement of the fire detection and alarm control panel and its detectors.

The A30XBI adapter can be used with conventional and analog detectors, and are supplied configured in relation to the detectors to be replaced.

Key features

Technical Data Sheets

Zócalo adaptador A50BI

A50BI adapter socket

Zócalo adaptador A50BI

A50BI adapter socket

To facilitate the task of upgrading the A30X range detectors to the new A50 range detectors, Cofem has an “interconnection base”, which allows the new detectors to be placed on the previous range sockets, without the need to change or rewire the sockets.

In this way, if the wiring and sockets of the installation are in good condition, a quick, simple and very economical upgrade of the system can be carried out, based on the replacement of the fire detection and alarm control panel and its detectors.

The A50BI adapter can be used with conventional and algorithmic addressable detectors.

Key features

Technical Data

Download

Manuals

Download