Software I - Link Lite

I-Link Lite
I-LINK LITE is a computer software specifically designed for the configuration and management of conventional Silver control panels.
This system allows configuration through an intuitive graphical interface, facilitating the customization of the main functionalities of the control panels, and adapting to the particular needs of each installation.
Key features
- Compatibility with Windows operating systems.
- Advanced configuration of the main functionalities of the plants.
- Customization of labels for zones and exits.
- Programming of activation sequences of the main and logic outputs, adapted to different situations.
- Download and management of the control panel’s event history.
Technical Data Sheets
Manuals
Central Silver

Central Silver
Conventional automatic fire detection and alarm control panel with up to 16 zones and 16 configurable relay outputs; this control panel is characterized by having independent zones and relay outputs.
In terms of zones, different models are contemplated to adapt in the most precise way to the needs of each installation with 2, 4, 8, 12 or 16 zones. As for relay outputs, the control panel supports up to 2 relay cards of 4 or 8 relays.
Additionally there are two variants of relay cards: With all relay outputs dry contact or with all relay outputs supervised; the configuration of each relay is independent.
It is compatible with 4 types of relay modules:
- Module 4 voltage free relays: SVL4
- Module 8 voltage-free relays: SVL8
- Module 4 supervised relays: SVS4
- Module 8 supervised relays: SVS8
The control panel can be connected to the analog loop of the Lyon system as an additional point.
Modbus, CRI, I-Link and Remote versions are available.
Key features
- Central with models of 2, 4, 8, 8, 12 or 16 zones with capacity to incorporate up to 32 elements per zone.
- Ability to include 4, 8, 12 or 16 relay outputs. These relays can be supervised (wet contact output) or without
supervising (dry contact output NO/NC). - 2 general siren outputs, supervised and with delayed activation from 0 to 10 minutes and protected by an auto
resettable fuse. - 1 dry contact alarm output and immediate activation named ALARM.
- 1 fault output, dry contact and delay activation between 0 and 10 minutes, protected by a resettable fuse
named FAULT. - 2 auxiliary 30VDC outputs, named 30V (non-resettable) and 30VR (resettable), both protected by a fuse, capable of
providing external power supply to elements such as fire door electromagnets, external sirens, relay modules
, etc. - 2 supervised general siren outputs, S1 and S2, with independent delay activation between 0 and 10 minutes, protected
by resettable fuses. - It incorporates, by default, the Spanish and English languages.
- Metal box with front screwed door, 13 pre-drilled holes of 28mm diameter for wiring and
space for 2 batteries of 12V and 7Ah. - Measures 320x415x130mm.
- IP30 protection.
- Certified according to EN54-2/A1 and EN54-4/A1.
Technical Data Sheets
Manuals
Socket for detectors D50Z0 and D50ZAL

Socket for detectors D50Z0 and D50ZAL
Socket for fire detection and alarm detectors of the A50 and C50 range.
There are 2 versions: with low socket or with high socket (prepared for connection with 20 mm diameter pipe).
Key features
Technical Data Sheets
Manuals
Optical thermal detector C50SH

Optical thermal detector C50SH
Conventional optical-thermal detector
The C50 range of detectors is based on a new refined aesthetic that integrates the latest electronic technology with new, more efficient detection algorithms and a three-dimensional design that makes it more robust to environmental dirt.
The C50 range allows multiple combinations between optical and thermal detection.
The model C50SH is a detector with two different types of sensors: An optical smoke sensor and a thermal sensor.
The optical sensor is specially designed to detect the presence of combustion aerosols in a three-dimensional design that makes it more robust to dirt.
For its part, the thermal sensor allows the thermovelocimetric response of the detector to be activated at a static temperature of 60ºC in the case of slow fire development.
Key features
- Optical and thermal sensor.
- Low profile, overall height less than 55 mm (including socket).
- Also available with high socket for 20 mm pipe.
- Possibility of connection to a remote action indicator.
- Easy connection, no polarity.
- Steady red LED to indicate its alarm status.
- Signaling of idle status by simple flashing of the LED every 10 seconds.
- Signaling of high soiling status by double flashing of the LED every 10 seconds.
- Easy-to-install head and socket, interchangeable throughout the C50 range, and made of white heat-resistant ABS.
- Certified by AENOR according to EN 54-5 class A2R and EN 54-7 with CE marking according to the European Construction Products Regulation (EU) No. 305/2011.
Technical Data Sheets
Manuals
Thermal Detector C50TB

Thermal Detector C50TB
The C50 range of detectors is based on a new refined aesthetic that integrates the latest electronic technology with new, more efficient detection algorithms and a three-dimensional design that makes it more robust to environmental dirt.
The C50 range allows multiple combinations between optical and thermal detection.
The model C50TB is a detector with a thermal sensor.
The C50TB detector is ideal in situations where the premises or building to be protected operates in warmer environments, and it is necessary for the detector to go into alarm at higher temperatures. The C50TB detector is set for a trigger temperature in static conditions of 70ºC.
Key features
- Thermal sensor.
- Low profile, overall height less than 42 mm (including socket).
- Also available with high socket for 20 mm pipe.
- Possibility of connection to a remote action indicator.
- Easy connection, no polarity.
- Steady red LED to indicate its alarm status.
- Easy-to-install head and socket, interchangeable throughout the C50 range, and made of white heat-resistant ABS.
- Certified by AENOR according to EN 54-5 class B (model C50TB), with CE marking according to the European Construction Products Regulation (EU) No. 305/2011.
Technical Data Sheets
Manuals
Thermal Detector C50T

Thermal Detector C50T
The C50 range of detectors is based on a new refined aesthetic that integrates inside the latest electronic technology with new more efficient detection algorithms and a three-dimensional design that makes it more robust to environmental dirt.
The C50 range allows multiple combinations between optical and thermal detection.
The C50T model is a detector with a thermal sensor.
The C50T model is set to trigger at static ambient temperatures of 60ºC.
Key features
- Thermal sensor.
- Low profile, overall height less than 42 mm (including socket).
- Also available with high socket for 20 mm pipe.
- Possibility of connection to a remote action indicator.
- Easy connection, no polarity.
- Steady red LED to indicate its alarm status.
- Easy-to-install head and socket, interchangeable throughout the C50 range, and made of white heat-resistant ABS.
- Certified by AENOR according to Standard EN 54-5 class A2 (model C50T), with CE marking according to the European Construction Products Regulation (EU) No. 305/2011.
Technical Data Sheets
Manuals
Thermal Detector C50S

Thermal Detector C50S
Conventional optical detector
The C50 range of detectors is based on a new refined aesthetic that integrates inside the latest electronic technology with new more efficient detection algorithms and a three-dimensional design that makes it more robust to environmental dirt.
The C50 range allows multiple combinations between optical and thermal detection.
The C50S model is a detector with an optical smoke sensor.
The optical sensor is specially designed to detect the presence of combustion aerosols in a three-dimensional design that makes it more robust to dirt.
Key features
- Optical sensor.
- Low profile, overall height less than 42 mm (including socket).
- Also available with high socket for 20 mm pipe.
- Possibility of connection to a remote action indicator.
- Easy connection, no polarity.
- Steady red LED to indicate its alarm status.
- Signaling of idle status by simple flashing of the LED every 10 seconds.
- Signaling of high soiling status by double flashing of the LED every 10 seconds.
- Easy-to-install head and socket, interchangeable throughout the C50 range, and made of white heat-resistant ABS.
- Certified by AENOR according to Standard EN 54-7 with CE marking according to the European Construction Products Regulation (EU) No. 305/2011.
Technical Data Sheets
Manuals
Thermal Detector C50H

Thermal Detector C50H
Conventional thermal detector with thermovelocimetric response
The C50 range of detectors is based on a new refined aesthetic that integrates inside the latest electronic technology with new more efficient detection algorithms and a three-dimensional design that makes it more robust to environmental dirt.
The C50 range allows multiple combinations between optical and thermal detection.
The C50H model is a detector with a thermal sensor.
The thermal sensor allows the thermovelocimetric response of the detector, activating at a static temperature of 60ºC in the case of slow fire development.
Key features
- Thermal sensor.
- Low profile, overall height less than 42 mm (including socket).
- Also available with high socket for 20 mm pipe.
- Possibility of connection to a remote action indicator.
- Easy connection, no polarity.
- Steady red LED to indicate its alarm status.
- Signaling of idle status by simple flashing of the LED every 10 seconds.
- Easy-to-install head and socket, interchangeable throughout the C50 range, and made of white heat-resistant ABS.
- Certified by AENOR according to Standard EN 54-5 with CE marking according to the European Construction Products Regulation (EU) No. 305/2011.
Technical Data Sheets
Manuals
Base with alarm C50ZSD

Base with alarm C50ZSD
Remote action indicator of the conventional fire detection system.
The PIAL allows to display the alarm indication of detectors of the conventional Cofem system.
Typical use cases:
- Places where the elements of the detection system are not visible, such as inside false ceilings, where the PIAL can be placed visibly on the underside of the ceiling or close to the wall.
- Rooms with reduced accessibility or where a long inspection path is required to identify the item in alarm, such as in hotel rooms, where the PIAL can be placed on the door frame of each room making it very easy to identify it.
The PIAL shows the alarm status by the permanent activation of the red light.
It is a simple element to install, both for its electrical connection and for its fastening. In addition, it can be adapted to the mechanism boxes or switchgear.
Key features
- Allows you to identify the alarm status from any direction perpendicular to your installation.
- Easy connection, with polarity.
- It can be installed on top of switch boxes or switchgear.
- Red light produced by two LEDs, which increases its reliability in case of failure of any of them.
- Made of heat-resistant ABS. The base and cover are white, the visor is red.
Technical Data Sheets
Manuals
Base with alarm C50ZSL

Base with alarm C50ZSL
Socket for conventional C50 detectors with EN 54-23 certified base with visual alarm and EN 54-3 sound.
There are 2 models available:
C50ZSL: D50 socket with sound and light base, addressable.
C50ZSD: D50 socket with sound base, addressable.
Typical uses for the C50ZSL and C50ZSD are spaces or rooms that require an integrated fire detector with siren and visual alarm such as hotel rooms.
The coverage of the set should not exceed the coverage of the fire detector with which it is installed, unless justified by the reason or use.